应用
适合于蒸汽管道、锅炉及其他对温度、压力、流速有所要求的场所。
主要技术参数 电气出口:M20x1.5,NPT1/2
连接尺寸:M20x1.5,NPT1/2
防护等级:IP65
型号及规格
型号 |
分度号 |
测温范围 ℃ |
公称压力 |
流速 |
规格 Lxl |
WRN-01T WRN2-01T |
K |
0-800 |
≤ 30MPa |
≤ 100m/s |
—— |
WRE-01T WRE2-01T |
E |
0-600 |
WZP-01T WZP2-01T |
Pt100 |
-200-+500 |
WRN-624 WRN2-624 |
K |
0-800 |
≤ 30MPa |
≤ 80m/s |
绝缘式 |
WRE-624 WRE2-624 |
E |
0-600 |
WZP-624 WZP2-624 |
Pt100 |
-200-+500 |
WRN-625 WRN2-625 |
K |
0-800 |
接壳式 |
WRE-625 WRE2-625 |
E |
0-600 |
WRN-012T WRN2-012T |
K |
0-800 |
≤ 10MPa |
—— |
440x230 640x430 840x630 1340x1130 2500x1200 640x430 3000x1500 3500x1700 |
WRE-012T WRE2-012T |
E |
0-600 |
WZP-012T WZP2-012T |
Pt100 |
-200-+500 |
WRN-12AT WRN2-12AT |
K |
0-800 |
WRE-12AT WRE2-12AT |
E |
0-600 |
WZP-12AT WZP2-12AT |
Pt100 |
-200-+500 |
WRN-013T WRN2-013T |
K |
0-800 |
≤ 30MPa |
≤ 100m/s |
380x50 430x100 480x150 |
WRE-013T WRE2-013T |
E |
0-600 |
WZP-013T WZP2-013T |
Pt100 |
-200-+500 |
WRN-014T WRN2-014T |
K |
0-800 |
≤ 10MPa |
≤ 80m/s |
280x50 330x100 380x150 430x200 480x250 530x300 |
WRE-014T WRE2-014T |
E |
0-600 |
WZP-014T WZP2-014T |
Pt100 |
-200-+500 |
WRN-015T WRN2-015T |
K |
0-800 |
≤ 10MPa |
___ |
280x50 330x100 380x150 430x200 480x250 530x300 580x350 630x400 |
安装要求 对热电阻的安装,应注意有利于测温准确,安全可考及维修方便,而且不影响设备运行和生产操作.要满足以上要求,在选择对热电阻的安装部位和插入深度时要注意以下几点:
1、为了使热电阻的测量端与被测介质之间有充分的热交换,应合理选择测点位置,尽量避免在阀门,弯头及管道和设备的死角附近装设热电阻.
2、带有保护套管的热电阻有传热和散热损失,为了减少测量误差,热电偶和热电阻应该有足够的插入深度:
(1)对于测量管道中心流体温度的热电阻,一般都应将其测量端插入到管道中心处(垂直安装或倾斜安装).如被测流体的管道直径是200毫米,那热电阻插入深度应选择100毫米;
(2)对于高温高压和高速流体的温度测量(如主蒸汽温度),为了减小保护套对流体的阻力和防止保护套在流体作用下发生断裂,可采取保护管浅插方式或采用热套式热电阻.浅插式的热电阻保护套管,其插入主蒸汽管道的深度应不小于75mm;热套式热电阻的标准插入深度为100mm;
(3)假如需要测量是烟道内烟气的温度,尽管烟道直径为4m,热电阻插入深度1 m即可.
(4)当测量原件插入深度超过1m时,应尽可能垂直安装,或加装支撑架和保护套管.
工作原理 利用物质在温度变化时,其电阻也随着发生变化的特征来测量温度的。当阻值变化时,工作仪表便显示出阻值所对应的温度值。 |